Temperature Control System Solution Provider - Shanghai Yuexi Trade Development Co., Ltd

Shanghai Yuexi Trade Development Co., Ltd

Phone:(+86)189 1548 0537

Phone

(+86)189 1548 0537
PAC26P high-precision single-phase power regulator
◆40A-550A
◆ Frequency adaptive
◆ High precision power regulator
◆ Slow start, emergency stop
◆ Constant current/constant voltage/current limiting
◆ Overtemperature and overcurrent alarm

◆ Suitable for resistive and inductive loads

◆ CE certification

Product Details
Technical Specifications
Product Model
Product size

Shanghai Yuexi Trade Development Co., Ltd. power regulator design concept


Features of PAC26P Single-Phase Power Controller

The PAC26P Single-Phase Power Controller is primarily designed for export, featuring a wide application voltage range and frequency adaptability. It offers optional constant current and constant voltage modes, as well as optional overcurrent and overvoltage protection. It is particularly suitable for environments with unstable voltage and frequency (e.g., self-generated power scenarios). It is compatible with resistive loads and inductive loads such as transformers, silicon carbide rods, molybdenum wires, and graphite. The module uses German imported or domestic modules.

1 Load Control Element
hyristor (SCR) Module
2 Load Power Supply
Single-phase 220V AC  Three-phase 380V AC ±10% 50HZ
3 Control Input
4~20mA   input, receiving impedance 120Ω
4 Output Resolution
Phase Control: 0.6°; Power Control: 20ms
5 Phase Shift Range
0~175°
6 Drive Output
1). Output: 12V pulse, variable pulse width, maximum drive current: < 30mA. Compatible with P-type SSR, integrating voltage regulation/power control functions.
2). Pulse transformer output: slotted pulse, compatible with MKK/MTC anti-parallel modules, enabling single-phase voltage regulation and full-control rectification, but without power control mode.
7 LED Status Indicator
Green: INPUT signal linear indicator light.
Tricolor status lights: RUN green operation light; ALM red alarm light; STOP yellow flashing standby light。
8

Soft Start and Soft Shutdown RS for External 

Actuator Switch

No Voltage Contact Input
Closed (ON): Soft shutdown, fixed time of 3 seconds;
Open (OFF): Operation. (Soft start time set by internal potentiometer P3, 0.2 to 120 seconds)
Not Connected: Operational status.

9

Automatic soft start and 

emergency stop during operation

Emergency stop due to overcurrent or overtemperature during operation, with the protection response time for overcurrent and overtemperature not exceeding one power cycle (20ms).
10 70℃ Overtemperature Protection

Voltage-free Normally Closed Contact
Open Circuit: Overtemperature
Reset: After troubleshooting,reset the start/stop switch or power on again.

11 Alarm Relay
One set of normally open contacts (pure resistance 1A 250VAC).
12 Alarm Type
Overcurrent, Heatsink Overtemperature.
13 CT Maximum Current Limit

External 10K potentiometer, adjustment range 20% to 100%.
To cancel: Leave the CT input terminal open or adjust the external potentiometer R3 to maximum.

14 Overcurrent Protection

Adjusted by internal potentiometer P2. Reference point 1V;
Overcurrent multiple: Twice the reference set point (=2V)
Action time: <20ms.

High-Precision Single-Phase PAC26P Power Controller Selection Table
Code
Basic parameters
PAC26P-
Input Signal: 4-20mA, Acceptable Impedance: 100Ω, Output Type: Voltage Regulation. Soft Start Time Adjustable from 0-120 Seconds, Alarm Output: Normally Open, 1A/240V AC, Suitable for Resistive and Inductive Loads. Features Configurable Constant Current and Overcurrent Protection, Frequency Adaptive, High Output Resolution. Welcome to Purchase.
Radiator unit
Overall dimensions of the whole machine
SCR specifications
Load Maximum Current
B100C-: 1 fan, maximum current per phase is 160A at an ambient temperature of 45 degrees; maximum current per phase is 180A at an ambient temperature of 40 degrees.


L 272 x W 128 x D 211mm 

Single-hole mounting

 hole diameter 10mm


SKKT106A
100A
SKKT162A
150A
MKKT55A
40A
MKKT70A
50A
MKKT90A
63A
MKKT110A
77A
MKKT160A
120A
MKKT180A
140A
MKKT200A
150A
B120C-: 1 fan, maximum current per phase is 200A at an ambient temperature of 45 degrees; maximum current per phase is 300A at an ambient temperature of 40 degrees.


L 280 x W 128 x D 241mm

Single-hole mounting

 hole diameter 10mm


MKKT250A
170A
MKKT300A
240A
SKKT273A
250A
SKKT330A
300A
B130C-: 1 fan, maximum current per phase is350A at an ambient temperature of 45 degrees; maximum current per phase is 450A at an ambient temperature of 40 degrees.


L330 x W 128 x D 241mm 

Single-hole mounting

 hole diameter 10mm


MKKT500A
300A
MKKT600A
400A
SKKT570A
550A

unitmm A B C
B100C 272 128 211
B120C 280 128 241
B130C 330 128 241